Liên hệ   
Board PLC FX3U-24MR-6AD-2DA - PLC Mitsubishi FX3U-24MR (14 ngõ vào, 10 ngõ ra transistor, 6AD, 2DA, RS232/RS485), Real time Clock (RTC)
Bảo hành: theo nhà sản xuất
Giao hàng 1-2 ngày
Ship COD toàn quốc
MÔ TẢ

Board PLC FX3U-24MR-6AD-2DA - PLC Mitsubishi FX3U-24MR (14 ngõ vào, 10 ngõ ra transistor, 6AD, 2DA, RS232/RS485), Real time Clock (RTC)
FX3U 24MR 14 điểm đầu vào 10 transistor đầu ra, 6 đầu vào tương tự (0-10 v) 2 analog kết quả đầu ra (0-10 v)
FX3U-24MR-6AD-2DA PLC programmable logic controller
14-point input, 10 transistoroutputs
X0-X5 high-speed input, can be accessed by three AB encoder, the default 12K, optional 100K
6 analog (3 0-10v, 3 0-20mA) 2 0-10v analog output
Power-down to maintain, can be set free
DC 24V power supply
3-way AB input
Support for 16-bit encryption,
Supports three kinds of interrupts,
485 communication Support 4 kinds of communication protocols,
Battery for Real Time Clock
Support 1N, 2N, 3U of the instructions,
Power-down to maintain their own set range,
Program 8000 steps,
Download speed 38400,
Floating-point operations,
HMI,
Scan 3000 steps 1ms 
Input Power
DC24
Number of steps
8000 steps; 2 communication ports: 1 RS232 (DB9 serial port is communication port for the FX3u protocol 38400,7,E,1; 1 RS485 (485 selection)  communication protocol can be set D8120).
X input element
X0-X27 DC24 input,Low level,X0-5 is a high-speed count input port (the Default is 12K, 100KHZ optional)
Y output element
Y0-Y11 for optimal relay output,relay output current 5A.
4 continuation electric apparatus 1 common end, altogether 3 common ends
Analog input
6 analog input, 12 bit precision,  3 channel analog input 0-10V, 3 channel analog input 0-20MA; read analog RD3A instruction
Analog output
2 analog output, 12 bit precision, output voltage: 0-10V. output analog voltage with WR3A instruction
Intermediate relay
M0-M3071, power-down save range can be set M0-M1023, the default M500-M1023
Step point
S0-1023, power-down save range can be set S0-S1023, the default S500-S9999
100Ms timer
T0-T199 Accumulated power-down saving T184-T199
10Ms timer
T200-T249 Accumulated power-down saving T246-T249
1Ms timer
T250-T383, where T250-255 is the cumulative type
16-bit counter
C0-C199, power-down save C100-C199
32-bit counter
C200-C219, save the power-down C220-C234
32-bit high-speed counter
C235-255; C235-C240 for the single-phase counter, not multiplier; C241-240 for the single-phase calculator, 2 octave; C2470249 for the dual-phase counter, not multiplier; C250-252 for dual-phase counter, ; C253-C255 for the dual-phase counter, 4 octave
Register D
D0-D7999, power-down save the range can be set D0-7999
Indirect addressing pointer V, Z
V0-7, Z0-7
P The subroutine jump number
P0-63
I interrupt
X0-5 external interrupt, timer interrupt (1MS unit) counter interrupt
Special M components
M8000 run-time normally closed, M8002 power pulse, M8011 is 10Ms pulse,
M8012 is 100Ms pulse, M8013 is 1s pulse, M8014 is minute pulse


Cable RS232